8 Detecting Alarms/Warnings Related to Communications or Commands

8-6

8.3 Monitoring Communication Data on Occurrence of an Alarm or

Warning

The command data received on occurrence of a data setting warning (A.94†) or a command warning

(A.95†) can be monitored using the following parameters. The following is an example of the data when an
alarm/warning has occurred in the normal state.

Command Data Monitor at Alarm/Warning Occurrence: Pn890 to Pn89E

Response Data Monitor at Alarm/Warning Occurrence: Pn8A0 to Pn8AE

Note: Data is stored in little endian byte order and displayed in the hexadecimal format.

Command

Byte Order

Command Data Storage at

Alarm/Warning Occurrence

CMD

RSP

1

Pn890.1 to 0

Pn8A0.1 to 0

2

Pn890.3 to 2

Pn8A0.3 to 2

3

Pn890.5 to 4

Pn8A0.5 to 4

4

Pn890.7 to 6

Pn8A0.7 to 6

5 to 8

Pn892

Pn8A2

9 to 12

Pn894

Pn8A4

13 to 16

Pn896

Pn8A6

17 to 20

Pn898

Pn8A8

21 to 24

Pn89A

Pn8AA

25 to 28

Pn89C

Pn8AC

29 to 32

Pn89E

Pn8AE

Example: Pn8A0 = 87 65 43 21