3.2 Commands Details

3-15

3

Commands for Preparation Process

3.2.7 Set and Save Parameters in Non-volatile Memory (PPRM_WR: 1CH)

Send a PPRM_WR command to save parameters in the SERVOPACK.

(1) PPRM_WR Command (1CH)

The specifications of the PPRM-WR command are described below.

Byte

PPRM_WR

Description

Command

Response

1

1CH

1CH

Phases in

which the

command can

be executed

Phase 2 and 3

Synchronization

classification

Asynchronous

command

2

ALARM

Processing

time

Within 200 ms

Subcommand

Cannot be used

3

STATUS

• Saves parameters in the non-volatile memory.
• For parameters that require turning the power supply OFF and ON again

to be validated, it is necessary to send a CONFIG command to validate
the settings.

• A warning will occur and the command will be ignored in the following

cases.
- NO is out of the range: Data setting warning 1 (A.94A)
- SIZE does not match: Data setting warning 4 (A.94D)
- PARAMETER is out of the range: Data setting warning 2 (A.94B)
- When writing parameters that affect utility functions currently being

used for operations with SigmaWin or a digital operator: Command
warning 1 (A.95A)

4

5

NO

NO

6

7

SIZE

SIZE

8

PARAMETER PARAMETER

9

10

11

12

13

14

15

16

WDT

RWDT

Do not turn off the power supply while the parameter is being written (CMDRDY = 0).