Yaskawa Sigma-5 User Manual: MECHATROLINK-II Commands User Manual

Page 140

Advertising
background image

B General-purpose Servo Control Command

A-5

App

Appendix

Select Motion (MOTION)

Select Latch Signal (L_SGN)

• Sequence Signals: SQ_CMD

• Combination of SVCTRL (3F) and Subcommands

Note:

√: Can be combined, ×: Can not be combined

D6

D5

D4

Motion

• During phase 1, Command warning 1 (A.95A)

will occur for POSING and FEED, and the com-
mand will be ignored.

• For INTERPOLATED, in all other phases except

phase 3, Command warning 1 (A.95A) will occur
and the command will be ignored.

0

0

0

HOLD

0

0

1

INTERPOLATE

0

1

0

FEED

0

1

1

POSING

D1

D0

Latch Signal

Meaning

0

0

Phase C

Encoder zero-point signal

0

1

EXT1

External latch signal 1

1

0

EXT2

External latch signal 2

1

1

EXT3

External latch signal 2

D7

D6

D5

D4

D3

D2

D1

D0

Reserved

Reserved

Reserved

Reserved

ACLR

Alarm clear

SEN

Sensor ON

BRK

Brake ON

SON

Servo ON

CODE Main Command

Subcommand

NOP

PRM_WR ALM_RD

PPRM_

WR

LTMOD_

ON

LTMOD_

OFF

SMON

3F

SVCTRL

×

Advertising