Epson Pro L30002UNL 30,000-Lumen HDR Pixel-Shift DCI 4K Laser 3LCD Large Venue Projector (White) User Manual
Page 200
200
Automatic light source calibration may not start in the following conditions:
• Within 20 minutes of turning on the projector.
• When using the Shutter feature or within 20 minutes of releasing the shutter.
• When using direct power shutdown.
• When you have used the projector continuously for over 24 hours.
Note:
To perform a light source calibration, the projector must have been on for at least 20 minutes and
the projector brightness must not be automatically dimmed due to high temperatures.
1.
Press the
Menu
button.
2.
Select the
Reset
menu and press
Enter
.
You see a screen like this:
3.
Select
Light Source Calibration
and press
Enter
.
4.
Select any of the following:
• To run the light source calibration now, select
Run Now
.
• To automatically run the light source calibration every 100 hours of projector usage, select
Run
Periodically
.
• To schedule automatic calibration, select
Schedule Settings
.