Viewing T1/E1 Local Statistics

Page 33-18

SEFS

. Severe Errored Framing Second. A second with one or more out-of-frame errors or an

AIS error.

LES

. Line Errored Seconds. The number of seconds during which one or more Line Code

Violation errors have occurred (see also the definition of Line Code Violation below).

CSS

. Controlled Slip Seconds. A one-second interval with one or more controlled slip errors.

Controlled slip errors are the replication or deletion of the payload bits on a frame. Such an
error may occur when there is a difference between the timing of a synchronous receiving
terminal and the received signal.

PCV

. Path Code Violations. A frame synchronization bit error in EF/

D4

and

E1

-no

CRC

frames,

or a

CRC

or frame synchronization error in the T1-

ESF

(Extended Super Frame) and

E1-CRC

frames.

LCV

. Line Code Violations. The occurrence of either a bipolar violation or excessive zeros

error. A bipolar violation is the occurrence of a pulse of the same polarity as the previous
pulse. In

B8ZS

and

HDB3

coded signals, a bipolar violation is a pulse of the same polarity as

the previous without being part of the zero substitution code. An excessive zeros error is the
occurrence of more than 15 contiguous zeros in an

AMI

-coded signal; in a

B8ZS

-coded signal,

it is the occurrence of seven (7) or more contiguous zeros.

Viewing Current Local Statistics

You can view statistics for the current 15-minute interval on a single port by entering the
following command

telcs <slot>/<port>

where

<slot>

is the slot number where the board is located, and

<port>

is the port number on

the board on which you want to view statistics. For example, to view 15-minute interval statis-
tics for Port 2 on the board in slot 5, enter

telcs 5/2

A screen similar to the following displays:

Local Current 15-minute Measurement for port 2 on slot 5


Circuit Identifier

: Alcatel T1 Circuit

Valid Intervals

: 1 of 96

Elapsed Time

: 431 of 900

ES

SES

BES

UAS

SEFS

LES

CSS

PCV

LCV

====== ====== ====== ====== ====== ====== ====== ====== ======

0

0

0

0

0

0

0

0

0

Definitions of the fields and columns in this display are the same as those used for the

telts

command. See Viewing Total Local Statistics on page 33-17 for an explanation of these statis-
tics.