The WAN Port Software Menu

Page 28-17

Clocking

This field sets the type of clocking used to clock transmit and receive data on the serial port.
If the clock goes out-of-phase, you will receive errors.

Note

The clocking value is only relevant if the port is a
physical

DCE

port (i.e.,

DCE

cable plugged into the

submodule

port). If the submodule port is a physical

DTE

port, clocking will default to External.

External Clocking

If you set this value to External, clocking will be controlled by the external

DCE

(a

DSU

or

other

DCE

device on the other end of the cable from the submodule port). External clock-

ing is the default option when the submodule is a physical

DTE

device (i.e., controlled by

an external

DCE

device).

When the submodule is acting as a physical DTE and

• the speed is greater than 256 kbps, or

• excessive FCS errors or Aborts are being detected coming from the submodule at the

remote port or line monitor

then it is recommended that the external DCE (usually a CSU/DSU) be set to take a trans-
mit data clock from the external DTE transmit clock (TXCE).

You can set up the external DCE this way by configuring its DTE, or dataport, configura-
tion options. Set the “Transmit Clock Source” to “External.” In this mode of operation, the
transmit clock is output by the DCE device and the submodule turns it around on the
external transmit clock back to the DCE, eliminating any phase misalignment between
transmit clock and transmit data.

If the external DCE does not provide a DTE configuration option for the transmit clock
source, then try setting the “Transmit Clock Polarity” to “Invert.” Note that Invert is the
clock polarity for Transmit (not Receive) and should only be used when excessive FCS
errors or Aborts are detected.

Internal Clocking

If you set this value to Internal, clocking is controlled by the internal

DCE

(the

submod-

ule

). Internal clocking should only be selected if the submodule is a physical

DCE

device

and you are using an RS-232 cable. Internal clocking is the default setting when the

submodule

is a physical DCE device and an

RS-232 DCE

cable is connected to this port.