Running frame fabric tests on omni switch/routers – Alcatel Carrier Internetworking Solutions Omni Switch/Router User Manual

Page 1056

Advertising
background image

Running Frame Fabric Tests on Omni Switch/Routers

Page 36-18

Running Frame Fabric Tests on Omni Switch/Routers

You can test the Omni Switch/Router

Multi VBUS

(

MVBUS

) backplane and the frame fabric

ASIC

of every switching module with the

framefab

command. The syntax for this command is

as follows:

framefab [<repeat_count> | ilb <repeat_count>]

The

<repeat_count>

option lets you set the number of times to run the test, which can be from

0 to 999. If you enter

0

, the

framefab

test will continue indefinitely. If you do not use the

<repeat_count>

option, then the

framefab

test will be executed once.

Using the

<repeat_count>

option requires the use of external cables or wrap plugs for the first

physical port of every switching module in the chassis. The external cables or wrap plugs
used in this test are identical to the one listed in the full duplex port test. See Omni
Switch/Router Port Test Wrap Cable/Plug Requirements
on page 36-10 for more information.

The

ilb

option, which can be used with the

<repeat_count>

option, performs an internal loop-

back. Using this option performs the

framefab

test without the use of external cables or wrap

plugs.

The chassis should be fully loaded (i.e., Omni Switch/Router modules in all slots) to achieve a
thorough testing of both the frame fabric

ASICs

and the Omni Switch/Router backplane. In

addition, an

MPX

should be installed in Slot 1.

To execute the framefab test indefinitely, for example, enter

framefab 0

at the system prompt. A screen similar to the following will be displayed.

Testing All Slots
Test In Progress: FABRIC Test

Test Summation:

Started: TUE OCT 27 18:40:31 2000

All Slots Passes Fails
FABRIC 1199 18

Failure Summation:

Test Fail No.

Test No.

Exp. Data

Meas. Data

Iter. No.

Time

Temp (C)

FABRIC

1

110402

00004cec

00000000

6

18:50:34

43.0

FABRIC

2

110504

0000a9e4

00000000

13

18:56:45

43.0

FABRIC

3

110307

0008a6ff

00000000

159

21:26:05

43.0

First 3 Failure(s) Detail:

Fail No. 1 - FRAME FABRIC TEST: Slot 5 failed. No packet Received from slot: 3
Fail No. 2 - FRAME FABRIC TEST: Slot 6 failed. No packet Received from slot: 5
Fail No. 3 - FRAME FABRIC TEST: Slot 4 failed. No packet Received from slot: 8