Ethernet Management Ports and Redundant Management Processor Modules

Page 6-7

Ethernet Management Ports and Redundant
Management Processor Modules

If redundant

MPXs

both have Ethernet management ports (

EMPs

), both

EMPs

in the switch will

have the same

IP

address if automatic file synchronization is enabled. If both

EMPs

are

plugged into the same subnet, the

UI

will show that there are duplicate

IP

addresses on the

network.

To get around this duplicate

IP

address problem, you must disable automatic file synchroniza-

tion and then you must configure different IP addresses for the two

EMPs

. To do this, perform

the following steps:

1. On the primary management module, enter

syncctl

at the system prompt. (See Setting Automatic Config Synchronization on page 6-15 for
more information on the

syncctl

command.)

2. If automatic file synchronization is already disabled, simply press

<Enter>

. If it is enabled,

enter

disable

at the prompt.

3. Enter

ethernetc

at the prompt. (See Configuring the Ethernet Management Port on page 6-5 for more
information on the

ethernetc

command.)

4. Enter

2=

followed by the

IP

address for the

EMP

on the primary management module.

5. Enter

save

at the prompt to save the

IP

address.

6. Enter

renounce

at the prompt to make the primary management module the secondary module and the
secondary module primary.

7. Log into the now primary management module.

8. On the now primary management module, enter

syncctl

at the system prompt.

9. If automatic file synchronization is already disabled, simply press

<Enter>

. If it is enabled,

enter

disable

at the prompt.

10. Enter

ethernetc

at the prompt.

11. Enter

2=

followed by the

IP

address for the

EMP

on the management module.