Replacing Power Supplies (9-Slot Chassis)

Page 1-30

Replacing Power Supplies (9-Slot Chassis)

If a power supply ever needs to be replaced in an Omni Switch/Router 9-slot Chassis (e.g.,
OmniS/R-9 or OmniS/R-9p), it is strongly recommended that power supplies not be mixed,
except under the conditions and exceptions shown in the following table.

Note

In all cases, swapping operations must be made with
the power switch of the replacement power supply
turned OFF. Failure to turn the power switch off during
the swapping operation may cause the data switch to
reset and restart.

Replacing Power Supplies (9-Slot Chassis)

If One of Two
Power Supplies
Fails

Revision

Replace

With

650-watt

Pre-M1

Both
Power
Supplies

Two 650-watt (Revision M1+)
or two 725-watt Power
Supplies

650-watt

M1 or later

Failed
Power
Supply

One 650-watt (Revision M1+)
or one 725-watt Power
Supply

725-watt

Any

Failed
Power
Supply

One 725-watt Power Supply