Trap Tables

Page 13-28

Trap Type

moduleChange

Object ID

1.3.6.1.4.1.800.3.1.1.4.0.2

Description

A module was either inserted or removed from the chassis. In some
cases, this trap may also be generated when a module is reset.

Bit Position
(Word 1)

1

Hex Value
(Word 1)

2

Trap Text
and
Variable
Descrip-
tions

Module was inserted or removed from chassis (slot 4, subunit 1, type 10)

Slot Number

. The slot number on

the front of the chassis where this
module was inserted or removed.

Submodule Type

. Indicates the submodule that was

inserted or removed. Typically this value will be 1,
meaning the base module was inserted or removed.
If this value is 2, then HSX module 1 was moved. If
this value is 3, then HSX module 2 was moved.

4 HSM
5 MPM
6

ESM 8-port 10BASE-T

7

ESM 16-port

8

TSM 6-port UTP/STP

9

FSM FDDI module

10

FSM CDDI module

11

ESM 4-port

12

ASM .5 MB multi-mode

13

ESM 12-port 10BASE-T

14

ESM 6-port universal module

15

MPM version II

16

ATM DS-3

17

FSM FDDI single mode

18

ASM .5 MB single mode

19

ASM UTP

20

ESM 8-port fiber

Module Type

. Indicates the module type that was inserted

or removed. The following integers are valid values:

21

ESM 12-port Telco

22

TSM fiber

23

ASM 2 MB multi-mode

24

ASM 2 MB single mode

25

WSM

26

WSM BRI

27

HSM2 base slot type

28

PizzaSwitch reserved

29

TSM CD-6

30

ASM 2 MB single mode

33

10Meg Ether Universal

34

ATM E3 (European)

35

Ether 100 FX Sngl Full Dup

36

Ether 100 FX Multi Full Dup

37

Ether 100 TX CU Full Dup

39

PizzaPort (repeater)

Advertising