Obtaining Status and Statistical Information

Page 29-47

Frame Relay Information

The statistics shown in the section are gathered at the Frame Relay protocol level.

Octets

The total octets, or bytes, received (first row) and sent (second row) on this port. The
third row shows the cumulative number of octets that have passed through the port (sent
and received). This statistic includes the data and Frame Relay header fields, but does not
include

CRC

or flag characters.

UniCast Frames

The total number of Unicast frames received (first row) and sent (second row) on this
port. The third row shows the cumulative number of Unicast frames that have passed
through this port (sent and received).

Unicast frames are destined for a specific virtual circuit, and are normally sent from one
local

DLCI

to the corresponding

DLCI

on the other side of the Frame Relay link. In Frame

Relay terms, these unicast frames are sent from a logical

DTE

, such as s

WSX

port, to a

Remote logical

DTE

, such as a

WSX

port on the other side of the Frame Relay link.

Discarded Frames

The number of frames discarded due to an error.

Error Count

Frames that contained Frame Relay type errors, such as

DLCMI

protocol errors and invalid

frame format. This count does not include standard physical errors, such as CRC and abort
errors.

Administrative/Operational Status

This field shows the Administrative and Operational Status of this

WSX

port. The status

indicator before the slash refers to the Administrative Status. If

UP

, then the port has been

enabled and can transmit data as long as its Operational Status is also UP. If the Adminis-
trative Status is

DN

, then the port will not pass data even if its physical connection is

good.

The status indicator after the slash refers to the Operational Status. If

UP

, then the port is

capable of passing data as long as it has been logically enabled at the Administrative
level. If

DN

, then the port cannot pass data due to a problem in the physical connection

(e.g., cable disconnected,

WSX

could not detect cable type) or because the port is Admin-

istratively Down.