Alcatel Carrier Internetworking Solutions Omni Switch/Router User Manual

Page 861

Advertising
background image

The WAN Port Software Menu

Page 28-35

ISDN-BRI Port Example

The following example displays the configuration view screen for an ISDN-BRI port (port 2).
To view 3/2, enter:

wpview 3/2

or

wpv 3/2

A screen similar to following displays:

Configuration View for Slot 3, Port 2.
1)

Admin Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UP

2)

Speed in BPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2048000

3)

Clocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Split

4)

Protocol Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Frame Relay

8) TOS for Voice Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . a0
9) TOS for Voice Signaling Data . . . . . . . . . . . . . . . . . . . . . . . . 60
10) TOS Mask for both TOS Value. . . . . . . . . . . . . . . . . . . . . . . . e0
11) Signaling IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.0.0.0
12) Signaling IP Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255.255.255.255
13) KeepAlive Up Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
14) KeepAlive Down Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
15) KeepAlive Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
16) DTR Pulse Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
17) DTR Pulse Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0

Note

The ISDN

wpview

menu displays PPP specific line

options described in the section Modifying a Port on
page 28-14. However, they do not apply to an ISDN
port, and are not described below.

Admin Status

The options for the Admin Status are

UP

and

DN

. If

UP

, the port has been enabled and

can transmit data as long as its Operational Status is also

UP

. If set to

DN

, the port will not

pass data even if its physical connection is good.

Speed in BPS

This field displays the access rate for the Frame Relay line to the service provider. This
parameter is the speed of the entire connection, not an individual virtual circuit. For
example, if you have a 56 kbps line to your service provider, this field should be set to
56000. A full T1 line would have an access rate of 1,544,000 bps, and a full E1 line would
have an access rate of 2,048,000 bps. For either T1 or E1, you can also have a fractional
service with an access rate that is a multiple of 64 kbps.

Clocking

This field displays either

External

,

Internal

, or

Split

. For a more detailed discussion of

clocking, see Clocking under Modifying a Port on page 28-14.

Protocol Type

The protocol type can be set to either Frame Relay or Point to Point Protocol (PPP). The
default setting is Frame Relay.