Configuring spanning tree port parameters, Configuring spanning tree port parameters -30 – Alcatel Carrier Internetworking Solutions Omni Switch/Router User Manual

Page 478

Advertising
background image

Configuring Spanning Tree

Page 17-30

Configuring Spanning Tree Port Parameters

The

stpc

commands allows you to configure port parameters (as opposed to bridge parame-

ters) for spanning tree. To configure port parameters

1. Enter the

stpc

command as shown:

stpc <groupNumber>

where

<groupNumber>

is the number of the group in the switch for which you want to

configure spanning tree port parameters. For example, to configure parameters for Group
1, you would enter:

stpc 1

As a variation of this command, you can enter the

stpc

command without specifying a

group. This will allow you to configure the port parameters on the currently selected
group. For information on how to select a group, see Selecting a Default Group on page
17-7.

A screen similar to the following is displayed:

Spanning Tree Port Configuration for Group 1 (Default GROUP (#1))

Port

Path

Enable

tx

Manual

Priority

Cost

Spanning Tree FA

Mode

Index

Slot/Intf/Service/Inst

(a)

(b)

(c)

(d)

(e)

--------

------------------------------

-----------

-------

---------------------

----

-----------

1

2/ 1/

Brg/ 1

128

10

y

NA

n

2

2/ 2/

Brg/ 1

128

10

y

NA

n

3

3/ 1/

Brg/ 1

128

10

y

NA

n

4

3/ 2/

Brg/ 1

128

10

y

NA

n

5

3/ 3/

Brg/ 1

128

10

y

NA

n

6

3/ 4/

Brg/ 1

128

10

y

NA

n

7

3/ 5/

Brg/ 1

128

10

y

NA

n

8

3/ 6/

Brg/ 1

128

10

y

NA

n

9

3/ 7/

Brg/ 1

128

10

y

NA

n

10

3/ 8/

Brg/ 1

128

10

y

NA

n

11

3/ 9/

Brg/ 1

128

10

y

NA

n

12

3/ 10/

Brg/ 1

128

10

y

NA

n

13

3/ 11/

Brg/ 1

128

10

y

NA

n

14

3/ 12/

Brg/ 1

128

10

y

NA

n

15

3/ 13/

Brg/ 1

128

10

y

NA

n

16

3/ 14/

Brg/ 1

128

10

y

NA

n

save|cancel|next|prev :

2. To modify a parameter, enter the index (row) number, column letter (

a

,

b

,

c

,

d

, or

e

), an

equal sign (=), and then the new parameter, as follows.

<index><column>=<new parameter>

For example, if you wanted to enable transmit Functional Address (

tx FA

in column

d

) for

the slot identified by

index 10

, then you would enter:

10d=y

Advertising