Trap Tables

Page 13-63

Trap Type

fddiLerFlagChange

Object ID

1.3.6.1.4.1.800.3.1.1.1.0.65

Description

The

LER

(Link Error Rate) flag on a port changed from

CLEAR

to

SET

.

Bit Position
(Word 3)

0

Hex Value
(Word 3)

1

Trap Text
and
Variable
Descrip-
tions

FDDI: Link Error Rate on a port is set (SMTIndex 1, port 2, LerFlag 3)

LER Flag

. The condition becomes

a c t i v e w h e n t h e v a l u e o f t h e
fddiPRTLerEstimate is less than or
equal to fddimibPORTLerEstimate.
The following integers are valid
values:

1

True

2

False

SMT Index

. A unique value for

each SMT (Station Management).
The value for each SMT must
remain constant at least from
one re-initialization of the enti-
ty’s network management sys-
tem to the next re-initialization.

Port index

. A unique value for each port

with in a given SMT, which is the same
as the corresponding resource index in
SMT. The value for each port must
remain constant at least from one re-ini-
tialization of the entity’s network man-
a g e m e n t s y s t e m t o t h e n e x t r e -
initialization.

Advertising