Running Hardware Diagnostics

Page 36-6

Running Hardware Diagnostics

The

test

command initiates one or more test routines on a switching module that you

specify. You can also optionally test all switching modules in one test session. Test status,
instructions, and a summary of results are provided as output. Start a diagnostic test session
using the following command syntax:

test <slot_number> [<repeat_count> [<test_name>]]

where

<slot_number>

Indicates the slot number in the Omni Switch/Router for the module on
which you want to run tests. If you enter

all

for this parameter, then all

switching modules in the chassis will be tested. This parameter is required;
if you do not enter a slot number then the test session will not start.

<repeat_count>

Indicates the number of times to run the specified tests on the module.
This value can be an integer between 0 and 999. A value of zero (0)
repeats the test infinitely. The default value is 1. This default will be
assumed if you do not enter a

repeat_count

.

<test_name>

Indicates the test to be performed on the module. You can indicate the test
name or

all

to run all tests. You can enter only one test name or

all

. The

default is

all

. This default will be assumed if you do not enter a

test_name

.

Note

A combination of

repeat_count

set to

0

and

test_name

set to

all

allows the user to run either the port test

infinitely or all off-board tests infinitely. If the user
chooses to run the port test when prompted, all the
static tests (memory and control/status register tests)
are run once, followed by an infinite run of the port
test. See Sample Command Lines on page 36-9 for
more information.

Descriptions of each test follows:

alpreg

Tests the Alpine registers. Test the Alpine control logic, registers, and
data/address lines.

csr

Tests the command/status registers. Includes testing management bus
buffers, management bus read/write control logic, reset and

LED

memory,

ID EEPROM

, and reset circuitry.

gigareg

Tests the Giga-Chip registers. Test the Giga-Chip control logic, registers,
and data/address lines.

hrexmem

Tests the

HRE-X

’s local memory. Includes testing the

HRE-X

read/write

functions, data/address, and the memory.

hrexport

Tests the

HRE-X

’s functions. Packets are generated by the

MPX

, sent out

to the port, and claimed by the

HRE-X

. The

HRE-X

will insert additional

routing information to the claimed packet and place it back on

MVBUS

to

be claimed and verified by the

MPX

. This test can be bypassed. See

Running Diagnostics on an Entire Chassis on page 36-20.

ilb

Performs a port test using the internal loopback at the

PHY

or framer

interface. Packets are generated by the

MPX

and sent out to the port and

returned through an internal loopback within the

PHY

or framer. The

MPX

verifies the packets on a bit by bit basis.

Advertising