Changing serial port communication parameters, Changing serial port communication parameters -2 – Alcatel Carrier Internetworking Solutions Omni Switch/Router User Manual

Page 166

Advertising
background image

Changing Serial Port Communication Parameters

Page 6-2

Changing Serial Port Communication Parameters

The serial communications parameters for the two

MPX

ports are set by default to the follow-

ing:

• 9600 bits per second (bps)
• 8 data bits
• 1 stop bit
• no parity

To change the serial port configuration parameters, follow the steps below:

1. Log into the switch. For instructions on logging in, see your Getting Started Guide.

2. At the system prompt, type

ser

.

3. You will see the following message:

Port to configure? {(C)onsole,(M)odem} (Console) :

Press

C

if you want to configure the console port (female, DCE) parameters, or type

M

to

configure the modem port (male, DTE) parameters. The default is the Console Port (

C

).

4. The current port values are shown, followed by a prompt to change the speed value.

Current Console (DCE) configuration:

9600 bps, 8 data bits, None parity, 1 stop bit, running Console (shell)
Speed (9600):

Enter the speed (in bits per second) at which you want the port to operate, or simply
press

<Enter>

to accept the default in parentheses. Valid values are

1200

,

9600

,

19200

, and

38400

bps.

5. The following prompt displays:

Data size {7/8} bits (8) :

Enter the data size in bits (7 or 8). The default is 8. Press

<Enter>

to accept the default in

parentheses.

6. The following prompt displays:

Parity { (N)one/(E)ven/(O)dd } (None) :

Enter the parity (none, even, odd) and press

<Enter>

. The default is None.

7. The following prompt displays:

Stop bits {0/1/2} (1):

Enter the number of stop bits (0, 1, or 2) and press

<Enter>

. The default is 1.

8. The following prompt displays:

Mode {(D)own,(C)onsole,(A)uxConsole,(S)LIP} (C) :

Advertising