Running Diagnostics on an Entire Chassis

Page 36-21

2) Stop on Failure

Enter

2

to halt diagnostics in an active state when a failure occurs or

1

(the default) to exit

diagnostics and display the

Test Summation

and

Failure Summation

sections of the

test

command output. Setting this field to

2

can be used to further troubleshoot problems.

However, setting this field to

2

requires more user intervention during a test.

3) Port Test Bypass

Enter

2

to complete testing of all ports regardless of port test failures or

1

(the default) to stop

testing at the first port failure. Setting this field to

2

can be used to further troubleshoot prob-

lems.

4) Port Test Type

Enter

1

(the default) for a port test,

2

for an Internal Loopback (

ILB

) test,

3

for a stress test, or

4

for an

ILB

stress test. External cables are required for the port and stress tests but not for the

ILB

test. In addition, the stress test requires a special image file (see Running Diagnostics on

page 36-2) and is only available for Ethernet (

ESX

and

GSX

) modules on the Omni

Switch/Router.

Note

Option 5,

HRE-X Test Mode

, is for the Omni

Switch/Router only.

5) HRE-X Test Mode

This option lets you configure port tests for

HRE-Xs

installed on Omni Switch/Router switch-

ing modules. It does not affect the port test for

HRE-Xs

installed on

MPXs

. Currently, the port

test on

HRE-Xs

installed on switching modules runs in conjunction with the normal port test.

Each physical port is tested with the normal port test path and then through the

HRE-X

port

test path before testing the next physical port. Subsequent physical ports are tested with only
the normal port test path.

Enter

1

to bypass testing of the

HRE-X

when the port test is run or

2

to perform the test as

described above.