You may remove and insert switching modules while the switch is running. This technique is
referred to as “hot swapping.” When you hot swap, you must replace the module with the
same module type as the one you removed. For example, if you remove an

ESX

switching

module you must replace it with another

ESX

switching module.

Note

You cannot hot swap a module into a previously
empty slot. To use an empty slot, you must power
down your chassis.

Perform the following steps to safely hot swap a switching module. (You cannot hot swap a
primary

MPX

module.) Since this procedure could possibly disrupt the network, it is best to

hot swap during network down times.

1. At the system prompt, enter

swap on <minutes>

where

minutes

is the number of minutes you want the switch to be in swap mode (the

default is 5 minutes). A message similar to the following will be displayed.

Swap is ON for 5 minutes

The swap mode must be enabled (

ON

) to insert a switching module. If not, the system

may halt or restart. (See Chapter 6, “Configuring Management Processor Modules,” for
more information on the

swap

command.)

Caution

Modules can only be reset and hot-swapped when the

MPX’s

OK2

light is in its normal flashing green state.

2. Enter

reset

, followed by the slot number of the switching module you want to hot swap,

then followed by the word

disable

. (See Chapter 36, “Running Hardware Diagnostics,” for

more information on the

reset

command.) For example, if you want to hot swap the

switching module in slot 4, you would enter

reset 4 disable

at the system prompt. Next, the switch will prompt you to confirm the reset. The follow-
ing is an example of the display for an

ESX

module. The display for other types of switch-

ing modules will be similar.

Resetting slot of type F-Ether/M may crash system
Attempt reset anyway {Y/N}? (N) :

Press

y

and then press

<Enter>

. If the switching module is in slot 4, a message similar to

the following will be displayed.

resetting slot 4 to disable

3. The

MPX’s

OK2

LED

will flash amber 1 or 2 times, then return to normal flashing green.

The switching module’s

OK1

LED

will turn amber and the

OK2

LED

will not be illumi-

nated. Remove all cables attached to ports on the switching module that you are going to