Modifying a frame relay pvc backup service, Modifying a frame relay pvc backup service -10 – Alcatel Carrier Internetworking Solutions Omni Switch/Router User Manual

Page 1020

Advertising
background image

Backup Services Commands

Page 34-10

Modifying a Frame Relay PVC Backup Service

To modify a backup service for a frame relay PVC:

1. First, enter the

bsmodify

command, followed by the index of backup service, followed by

<return>

, as shown in the example below:

/Interface/backup % bsm b2 <return>

A screen similar to that shown below will display:

1) Description

: Backup 1

2) Admin Status { (E)nabled, (D)isabled }

: Enabled

Primary Type

: Frame Relay PVC

Slot

: 3

Port

: 3

DLCI

: 32

Backup Type

: PPP Peer

Peer ID

: 1

5) Startup Timer Value

{Time in Seconds after

System Startup to wait
for Primary to come up
before activating
Backup }

: 300

6) Activate Timer Value

(Time in Seconds after
Primary Failure to
activate Backup }

: 10

7) Restore Timer Value

{Time in Seconds after
Primary restoral to
disable Backup }

: 10

(save/quit/cancel)
:

The command functions in a manner similar to the

create

command, except the parame-

ters that define the backup service may not be changed. These parameters are the:

• index

• primary type

• primary type subparameter

• backup type, and

• backup type subparameters.

Only the Description and Timer fields may be modified.

2. Once you are satisfied with the values, enter the

save

command, followed by

<return>

at

the prompt, as shown below:

: save <return>

A screen similar to that shown below will display:

Backup Service Index 2 modified.
/Interface/backup %

Advertising