Trap Tables

Page 13-40

Trap

moduleResetReload

Object ID

1.3.6.1.4.1.800.3.1.1.4.0.17

Description

The specified module has been either reset or reloaded. A reload may
occur during a firmware download.

Bit Position
(Word 1)

16

Hex Value
(Word 1)

1 0000

Trap Text
and
Variable
Descrip-
tions

Module reset or reloaded by chassis manager (slot 4 subunit 1 type 6 status 3)

Module Type

. Indicates the module type that was reset or

reloaded. The following integers are valid values:

Submodule Type

. Indicates the submodule that was reset or reloaded.

Typically this value will be 1, meaning the base module was reset or
reloaded. If this value is 2, then HSX module 1 was affected. If this
value is 3, then HSX module 2 was affected.

Operational State

. Indicates the current state of the module that was reset or reload-

ed. The following integers are valid values:

1

Unknown state. The module may have failed low-level self-test.

2

Invalid. The module may exist, by the chassis does not have control of it.

3

Operational. The module is running fine with no errors.

4

Disabled. The module has been set to disable through the UI or SNMP.

5

Reset. The module has been reset.

6

Loading. The module is in the middle of loading.

7

Testing. The module is in self-test.

8

Warning. A warning was detected during operation.

9

Non-fatal error. A non-fatal error was detected during operation.

10

Fatal error. A fatal error occurred during operation. The module may or may
not be functional.

13

ESM 12-port 10BASE-T

14

ESM 6-port universal module

15

MPM version II

16

ATM DS-3

17

FSM FDDI single mode

18

ASM .5 MB single mode

19

ASM UTP

20

ESM 8-port fiber

21

ESM 12-port Telco

22

TSM fiber

23

ASM 2 MB multi-mode

24

ASM 2 MB single mode

4 HSM
5 MPM
6

ESM 8-port 10BASE-T

7

ESM 16-port

8

TSM 6-port UTP/STP

9

FSM FDDI module

10

FSM CDDI module

11

ESM 4-port

12

ASM .5 MB multi-mode

.

Slot number.

The slot number of the

module that was reset or reloaded.

Advertising