Remote Network Monitoring (RMON)

Page 14-3

Remote Network Monitoring (RMON)

Remote Network Monitoring (

RMON

) allows you to set up remote monitoring within your

Omni Switch/Router.

RMON

consists of “probes” and “events.” There are two commands in

the Networking menu,

probes

and

events

, which you can use to monitor, activate and inacti-

vate probes and events. Be aware that you cannot create probes from within the switch’s User
Interface; to do so requires a network application such as

HP

ProbeView.

Probes and Events

A

probe

is a task that runs in the switch. By using probes instead of sending repetitive inquir-

ies to the switch, network traffic is significantly reduced.

There are three different kinds of probes: Ethernet, History, and Alarm.

A network management station (

NMS

) can configure either History or Alarm probes (a maxi-

mum of 16 is allowed). The status of a probe can be one of the following:

• Creating - The probe is under creation.

• Active - The probe is active.

• Inactive - The probe is inactive.

An

event

is an action that takes place based on an alarm condition detected by a probe. The

event can take the form of an

SNMP

trap message and/or a log entry describing the alarm.

Ethernet Probes

An Ethernet probe monitors a selected Ethernet interface (port) and tracks Ethernet statistics.
An Ethernet probe is automatically created on each Ethernet interface that is enabled. If the
interface becomes disabled, that Ethernet probe is deleted.

History Probes

A History probe keeps a running history of all the statistics it has collected. When you set up
a history probe you assign a sampling interval and a total number of samples to be taken. It
keeps this information in a set of rotating buffers, so that it always retains the most recent
samples.

The sampling rate is configurable from 1 second to 3600 seconds (1 hour). The total number
of samples is configurable, however, it is limited by system resources (memory) available. The
more samples you request, the more system resources needed. You may request as many
samples as you want but the system will only grant as many as it has available.

Alarm Probes

An Alarm probe generates an alarm if the variable you are monitoring exceeds a set limit.

To set up an Alarm probe you need to select a variable (Ethernet statistic) that you want to
monitor. You set an upper and lower threshold that you will allow this variable to reach. If it
crosses the threshold, an event is triggered which results in the sending of an

SNMP

trap and/

or the logging of the alarm.

There are two ways an Alarm probe monitors variables. One is by absolute value. For exam-
ple, if you set an upper limit of 100, an alarm will be generated if the variable exceeds 100.
The other is a delta value where you can set the amount of change allowable; for example,
you could set the delta range to 10. If the current sample differs from the previous sample by
more than 10, an alarm will be generated.