4

until you complete the configuration for all pairs. For more information, see "

SAN fast

configuration

."

5.

Monitor the SAN:

{

Create FC ping and FC tracert tasks to monitor fabrics. For more information, see "

Managing

FC ping tasks

" and "

Managing FC tracert tasks

."

{

Set alarm thresholds for FC ping tasks to receive alarms when the detected packet loss ratio
exceeds a defined alarm threshold. For more information, see "

Setting FC ping thresholds

."

Managing a TRILL network

1.

Create a DC in the VFM and import RBs to the DC. For more information, see "

Adding a DC

."

and "

Importing a network device

."

2.

Import RBs to the TRILL management module. For more information, see "

Importing RBs

."

3.

Synchronize the RB configuration to the VFM. Make sure the VFM gets the most recent RB

configuration before you configure or maintain the TRILL network. For more information, see
"

Synchronizing RBs

."

4.

Configure RBs and their interfaces to maintain the TRILL network. For more information, see

"Managing TRILL configuration of an interface

."

Managing an SPBN

1.

Create a DC in the VFM and import SPB devices to the DC. For more information, see "

Adding a

DC

." and "

Importing a network device

."

2.

Import SPB devices to the SPB management module. For more information, see "

Importing

devices

."

3.

Synchronize the SPB device configuration to the VFM. Make sure the VFM gets the most recent
SPB device configuration before you configure or maintain the SPBN. For more information, see

"

Synchronizing SPBM configuration

."

4.

Configure the MST region for the SPB devices and enable the ISIS-SPBM function on their
interfaces. For more information, see "

Configuring MST region parameters for multiple devices

."

and "

Enabling/disabling SPBM on interfaces

."

5.

Prepare the B-VLAN plan. See "

Creating a B-VLAN plan

."

6.

Create and deploy SPB services based on the B-VLAN plan. See "

Adding SPB services

." and

"

Deploying SPB services

."

7.

Display and error-correct the SPBN as follows:

{

Display the B-VLAN, VSI, and ACs of each SPB device. See "

Viewing SPBM configuration

."

{

Display interface state. See "

Managing interfaces

."

{

Locate the SPB devices that have the inconsistent configuration with the B-VLAN plan and

correct the configuration. See "

Deploying the B-VLAN plan to SPB devices

."

{

Audit SPB services. See "

Auditing SPB services

."

{

Map an SPB service to the ECT index of another B-VLAN. See "

Performing ECT migration

."

{

Display details of all ACs to obtain the connectivity between the SPBN and customer networks.
See "

Monitoring ACs

."