Chapter 3 Installation

3.1 Installation Environment

Avoid backlight, direct sunlight, and indirect sunlight.

For better identity authentication, there should be light source in or near the installation environment.

Sunlight, wind, hot/cool air from air conditioner and other external factors, which may affect surface

temperature, will create the deviation of the temperature measurement. In order to get an accurate

result, make sure the device is applied indoors and windlessly (where is relatively isolated from the

outdoors). The working temperature should keep between 50° and 95° F (10° and 35° C). If there are no

suitable environments for temperature measurement (the area faces the indoor and connects the

outdoor, the area at the door of the indoor environment, etc.), building a temporary temperature

measurement environment is suggested.

Influence Factors of Temperature Measurement:

­

Wind: The wind will take the heat away, which may affect the measurement result.

­

Sweat: The sweat will take the heat away, which may affect the measurement result.

­

Air Conditioner (Cool Air): If the indoor temperature is low, the surface temperature may also lower

than the actual temperature, which may affect the measurement result.

­

Air Conditioner (Heat) or Heating: If the indoor temperature is high, the surface temperature may also

higher than the actual temperature, which may affect the measurement result.

In order to make the device work properly, you should wait for 90 min after the device is powered on.

For details about installation environment, see

Tips for Installation Environment

.

3.2 Wall Mounting

3.2.1 Flush Mounting

NOTE:

The hole distance of the gang box is 83.3 mm to 83.5 mm.

The additional force shall be equal to three times the weight of the equipment. The

equipment ad its associated mounting means shall remain secure during the installation.

After the installation, the equipment, including any associated mounting plate, shall not be

damaged.

Select the mounting method according to your actual situation.

1.

Make sure the gang box is installed on the wall.