Chapter 2 Setting Up XSCF

2-53

After the XSCF reset, the XSCF session is disconnected. Please log in again to the
XSCF.

Specifying the Timeout Period of SSH/Telnet

Command operation

1. Use the showlogout (8) command to display the timeout period.

XSCF> showautologout

30min

2. Use the setautologout (8) command to set the timeout period.

<Example 1> Specify 255 (minutes) for the timeout period.

XSCF> setautologout -s 255

255min

The set timeout period becomes effective at the next login.

Installing and Uninstalling an SSH User Public Key

Command operation

1. Use the showssh (8) command to display the user public key.

<Example> The user key is not set.

XSCF> showssh -c pubkey

XSCF>

2. Generate the user private key and the user public key for a created XSCF user

account with your client software. See the manual for your client software for
procedures to create the user public key and to set the passphrase. We
recommend that the passphrase be set.

3. Use the setssh (8) command with option for installing user public key. Then,

copy and paste the user public key, which was made in

Step 2

, on the window

display. After pressing the Enter key, press the Ctrl-D key to complete the
installation.