Specifying the cpu operational mode – FUJITSU SPARC M4000 User Manual

Page 181

Advertising
background image

Chapter 2 Setting Up XSCF 2-125

Specifying the CPU Operational Mode

Command operation

1. Power off the domain.

2. Use the showdomainmode (8) command to specify the CPU operational mode.

XSCF> showdomainmode -d 0

Host-ID :0f010f10

Diagnostic Level :max

Secure Mode :on

Autoboot :on

CPU Mode :auto

3. Use the setdomainmode (8) command to set the CPU operational mode.

<Example> Specify SPARC64 VI compatible mode for CPU operational mode of domain

ID 0.

XSCF> setdomainmode -d 0 -m cpumode=compatible

Diagnostic Level :max -> -

Secure Mode :on -> -

Autoboot :on -> -

CPU Mode :auto -> compatible

The specified modes will be changed.

Continue? [y|n]:y

configured.

Diagnostic Level :max

Secure Mode :on (host watchdog: available Break-signal:non-receive)

Autoboot :on (autoboot:on)

CPU Mode :compatible

4. Use the showdomainmode (8) command to confirm that the CPU Mode is

compatible.

Note –

Restart the domain to apply the settings to the domain. You may set the

initial diagnostic level, enable or disable the host watchdog function, break signal,
automatic boot, and CPU operational mode.