FUJITSU SPARC M4000 User Manual

Page 59

Advertising
background image

Chapter 2 Setting Up XSCF

2-3

Default user account: default

The user privileges are useradm, platadm.

Default password:

The default password is not input directly on the keyboard. Instead, after the
default user account is input, the mode switch of the operator panel is
operated as follows.

If Locked -> Change to Service -> Press return -> Keep the status for more
than 5 seconds. -> Change to Locked -> Press return

(Or if Service -> Change to Locked -> Press return -> Keep the status for more
than 5 seconds. -> Change to Service -> Press return)

This mode switch operation is done within one minute. When one minute is
passed, the authentication timeout occurs.

To begin the configuration, connect the XSCF Shell over a serial connection
using any terminal software. The shell can be used immediately following
connection to the serial port.

<Terminal screen image>

login:

Log in with the default user account. Follow the instructions to change the
mode switch of the operator panel, and operate the mode switch within one
minute.

login: default

Change the panel mode switch to Service and press return...

(Operation : Locked state -> Service -> Return)

Leave it in that position for at least 5 seconds. Change the panel

mode switch to Locked, and press return...

(Operation : Wait more than 5 seconds -> Service state ->

Locked -> Return)

XSCF>

Note –

When the server is running normally, the mode switch is set to the Locked

position.

Advertising