11 if an error occurs during xscf firmware update, 12 frequently asked questions, Frequently asked questions 8–18 – FUJITSU SPARC M4000 User Manual
Page 288
8-18
SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008
1. Repeat
and
. Then login to the XSCF on
the XSCF Web.
2. Display the firmware update menu.
3. Display the XSCF firmware version, and confirm it.
4. If you find an unmatched version of the replaced XSCF Unit, select the XCP
sync. In the window, match the version of the current firmware.
5. Display the XCP version and XSCF firmware version, and confirm them.
Confirming That the XSCF Firmware is Updated When the XSCF Unit
Has Been Replaced (in a System With a Single XSCF Unit or Both
Replacement in a System With Redundant XSCF Units)
1. Turn on power to the server after completing the XSCF Unit replacement task.
2. If the replacement unit and the replaced unit have different versions, a
message is displayed.
3. If the update has been performed, follow the procedure in
or
to update XCP, and confirm
the version.
8.1.11
If an Error Occurs During XSCF Firmware Update
If the system hangs or any of the messages shown below is output during the
firmware update, the XSCF Unit on the faulty side cannot be used and is treated as
a faulty component.
■
Case where the XSCF Unit is redundantly configured (on high-end systems)
Error involving a failed write or reset operation on the standby or active side
■
Case where there is one XSCF Unit (on midrange systems)
Error involved a failed write or reset operation
8.1.12
Frequently Asked Questions
Q: Is there any problem in executing reboot twice when applying the OpenBoot
PROM firmware?
There is no problem.