FUJITSU SPARC M4000 User Manual

Page 228

Advertising
background image

4-20

SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008

2. Use the setdualpowerfeed (8) command to enable or disable the dual power

feed of this system.

<Example 1> Enabling the dual power feed.

XSCF> setdualpowerfeed -s enable

disable -> enable

NOTE: Dual power feed will be enabled the next time the platform

is powered on.

<Example 2> Disabling the dual power feed.

XSCF> setdualpowerfeed -s disable

enable -> disable

NOTE: Dual power feed will be disabled the next time the platform

is powered on.

3. Confirm the new setting, and if it is correct, execute the rebootxscf (8)

command to reset the XSCF.

XSCF> showdualpowerfeed

disable -> enable

NOTE: Dual power feed will be enabled the next time the platform

is powered on.

4. Confirm whether the setting is valid after resetting the XSCF the next time.

XSCF> showdualpowerfeed

Dual power feed is enabled.