Chapter 8 Upgrade of XSCF Firmware and Maintenance

8-23

4. Set the encryption password used for encrypting the output log file.

5. Execute the data transfer. When the data transfer is complete, please contact

authorized service personnel.

Note –

The snapshot menu may be displayed as “Data Collector”.

Command operation

1. Connect a USB device to the USB connector mounted on the XSCF Unit front

panel.

2. Perform the snapshot (8) command and specify the local USB device on the

XSCF Unit for the output file (see Note).

XSCF> snapshot -d usb0

3. When the data transfer is complete, please contact authorized service

personnel.

Note –

For details on using the snapshot (8) command, including how to enable

encryption, see the man page or the XSCF Reference Manual.

Saving the Logs to a Specified Target Directory Over a Network

Web browser operation

1. Select the snapshot menu for saving the log menu and display the saving

operation page.

2. In the window, select the download button and specify the target directory.

3. Execute the data transfer. When the data transfer is complete, please contact

authorized service personnel.

Command operation

1. Perform the snapshot (8) command using a public key, specifying the target

directory, and specifying the encryption password for the output file.

XSCF> snapshot -t [email protected]:/home/joe/logs/x

:

2. When the data transfer is complete, please contact authorized service

personnel.