SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008

4. Use the testsb (8) command to check the PSB, then check the results by using

the showboards (8) command.

XSCF> testsb 0

Initial diagnosis is about to start. Continue? [y|n] : y

Initial diagnosis is executing.

Initial diagnosis has completed.

XSB Test Fault

---- ------- --------

00-0 Passed Normal

00-1 Passed Normal

00-2 Passed Normal

00-3 Passed Normal

XSCF> showboards -va

XSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD

---- - -------- ----------- ---- ---- ---- ------- -------- ----

00-0 SP Unavailable n n n Passed Normal n

00-1 SP Unavailable n n n Passed Normal n

00-2 SP Unavailable n n n Passed Normal n

00-3 SP Unavailable n n n Passed Normal n

01-0 SP Unavailable n n n Unknown Normal n

02-0 SP Unavailable n n n Unknown Normal n

2.2.13

Domain Mode Configuration

Domain mode configuration is used to specify the initial hardware diagnostic level,
enables or disables break signal suppression, enables or disables host watchdog,
enables or disables automatic boot and CPU operational mode for the specified
domain.

Note –

You may want to suppress some functions for a domain during system

operation or maintenance. For example, during system maintenance, you may not
want to use automatic boot (suppress automatic boot), suppress a break signal from
the console (enable break signal suppression), or suppress a panic during a Host
watchdog reset.