2 clearing the fault/degradation information, 7 changing the time, 8 switching the xscf unit – FUJITSU SPARC M4000 User Manual

Page 231: Clearing the fault/degradation information 4–23, Changing the time 4–23, Switching the xscf unit 4–23

Advertising
background image

Chapter 4 Operation of the Server

4-23

4.6.2

Clearing the Fault/Degradation Information

The information on a faulty or degraded component is cleared when the component
is replaced. For a component replacement, please contact a field engineer.

4.7

Changing the Time

The time of the server is based on the XSCF time. Time can be displayed or set to
local time or UTC. For details on displaying or setting the system time, see

Chapter 2

.

4.8

Switching the XSCF Unit

In some cases, such as when an error occurs in the LAN route of the XSCF Unit on
the active side in a system in which the XSCF Unit is redundantly configured, it may
be necessary to switch the active side over to the standby side.

The procedure for switching the XSCF Unit status from standby to active is as
follows:

Command operation

1. Log in the XSCF Unit on the standby side.

2. Use the switchscf (8) command to switch the XSCF Unit from standby status

to active status.

Note –

If possible, confirm that the ACTIVE LED states changes on the front panels

of both XSCF Units. Execute the switchscf (8) command only on one side (active
side or standby side) of the XSCF Units to automatically switch active/standby
status of the other XSCF Unit.

For specifying an option in the switchscf (8) command, see the XSCF Reference
Manual
.

Advertising