D-8

SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008

b. Establish a connection through the XSCF-LAN port, and use the XSCF Shell

to check error logs and other information. See

Appendix B

for the corrective

action.

c. Otherwise, check the XSCF event logs and server status by using the XSCF

Shell through the serial port.

Use the following commands to check the events that occurred at the time
the problem occurred:

showlogs error

showlogs event

showlogs power

showlogs monitor

showlogs console

fmdump

If you find an error, see

Appendix B

in this manual for the corrective

action.

d. Check the XSCF console log or panic log for the latest messages. A message

may have been output by the operating system after it detected the
problem. In cases involving a panic, use the
showlogs (8) command with
the panic option to check the events that occurred at the time the panic
occurred. For information about using the command, see the

XSCF Reference

Manual.

3. If you cannot find any problem after checking the above points, restart the

system.

4. If you find any problem, see

Appendix B

and take measures based on the

corrective action that is described, such as using the maintenance guidance of
the XSCF Shell command for replacement of the relevant component.