Turning on or off power to an i/o board or psu – FUJITSU SPARC M4000 User Manual
Page 236

4-28
SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008
Displaying and Setting the Locator LED State of Each Specified
Component in an External I/O Expansion Unit
■
Command operation
●
Use the ioxadm (8) command to display or set the locator LED state of the
specified component.
<Example 1> Display the locator LED states of an External I/O
Expansion Unit and components.
XSCF> ioxadm locator iox@12B4
Location Sensor Value Res Units
IOX@12B4 LOCATE Fast - LED
IOX@12B4/PS0 SERVICE Fast - LED
<Example 2> Set the locator LED state of PSU0 to on.
XSCF> ioxadm locator on iox@12B4/ps0
Location Sensor Value Res Units
IOX@12B4 LOCATE Fast - LED
IOX@12B4/PS0 SERVICE On - LED
Turning On or Off Power to an I/O Board or PSU
■
Command operation
●
Use the ioxadm (8) command to display, turn on or off power to the specified
component.
<Example 1> Display the PSU states of an External I/O Expansion Unit and
components.
XSCF> ioxadm -v list IOX@12B4
Location Type FW Ver Serial Num Part Num State
IOX@12B4 IOX 1.0 XCX033 5016937-03 On
IOX@12B4/PS0 A195 - T01056 3001701-03 On
IOX@12B4/PS1 A195 - T01074 3001701-03 On
IOX@12B4/IOB0 PCIX - XX00A3 5016938-04 On
IOX@12B4/IOB0/LINK OP 1.3 XF00X8 5017040-03 On
<Example 2> Turn off power to I/O board 0.
XSCF> ioxadm poweroff iox@12B4/iob0
<Example 3> Turn on power to I/O board 0 again.
XSCF> ioxadm poweron iox@12B4/iob0