Turning on or off power to an i/o board or psu – FUJITSU SPARC M4000 User Manual

Page 236

Advertising
background image

4-28

SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008

Displaying and Setting the Locator LED State of Each Specified
Component in an External I/O Expansion Unit

Command operation

Use the ioxadm (8) command to display or set the locator LED state of the
specified component.

<Example 1> Display the locator LED states of an External I/O

Expansion Unit and components.

XSCF> ioxadm locator iox@12B4

Location Sensor Value Res Units

IOX@12B4 LOCATE Fast - LED

IOX@12B4/PS0 SERVICE Fast - LED

<Example 2> Set the locator LED state of PSU0 to on.

XSCF> ioxadm locator on iox@12B4/ps0

Location Sensor Value Res Units

IOX@12B4 LOCATE Fast - LED

IOX@12B4/PS0 SERVICE On - LED

Turning On or Off Power to an I/O Board or PSU

Command operation

Use the ioxadm (8) command to display, turn on or off power to the specified
component.

<Example 1> Display the PSU states of an External I/O Expansion Unit and

components.

XSCF> ioxadm -v list IOX@12B4

Location Type FW Ver Serial Num Part Num State

IOX@12B4 IOX 1.0 XCX033 5016937-03 On

IOX@12B4/PS0 A195 - T01056 3001701-03 On

IOX@12B4/PS1 A195 - T01074 3001701-03 On

IOX@12B4/IOB0 PCIX - XX00A3 5016938-04 On

IOX@12B4/IOB0/LINK OP 1.3 XF00X8 5017040-03 On

<Example 2> Turn off power to I/O board 0.

XSCF> ioxadm poweroff iox@12B4/iob0

<Example 3> Turn on power to I/O board 0 again.

XSCF> ioxadm poweron iox@12B4/iob0

Advertising