XSCF Connection via a Serial Port

Establish an XSCF connection via a serial port. Connect the serial port as shown in

FIGURE 3-1

. An XSCF connection via the serial port has the following functions and

advantages:

■

XSCF Shell

■

Advantageous when connection to the LAN is not desirable for reasons of
security

■

Displaying the initial diagnostic message at the XSCF connection

XSCF Connection via XSCF-LAN and Serial Ports

Establish the XSCF connection via XSCF-LAN and serial ports. This type of
connection is also shown in

FIGURE 3-1

. The XSCF connection via both ports has the

following advantage in addition to those for the connection via the XSCF-LAN port.

■

A user who connected with the serial port can safely use the XSCF Shell.

3.2.2

XSCF-LAN and Serial Connection Purposes

The XSCF Unit has one serial port and two XSCF-LAN ports with 10/100 Mbps
interfaces. This section describes examples of using the XSCF-LAN ports and the
serial port.

Caution –

IMPORTANT

- The IP address of XSCF-LAN#0 and IP address of XSCF-

LAN#1 must be specified in different subnet addresses.

Using Two LAN Ports and Making the LAN Redundant

FIGURE 3-6

shows an example of a configuration where the two XSCF-LAN ports of

one XSCF Unit are used for the same purpose. This configuration makes the XSCF-
LAN redundant. The purpose is as follows:

■

The two LANs, which are redundantly configured, are used for the system
administrator

■

The two LANs, which are redundantly configured, are used for the remote
maintenance service.

■

FE uses either of the two LANs or a maintenance terminal that is serially and
directly connected.