Event

Meaning

SCF Reset:

The XSCF was reset.

Domain Power ON:

The domain power supply was turned on.

Domain Power OFF:

The domain power supply was turned off.

System Power ON:

The power supply of the server common section was turned on.

System Power OFF:

The power supply of the server common section was turned off.

XIR:

The XIR was reset.

Domain Reset:

The domain was reset.

B-6

SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008

Factor by which the power event was instructed (Cause). The causes and their
meanings are as follows:

Cause

Meaning

Self Reset:

Self-resetting of the XSCF reset the XSCF.

Power On:

Turning on the input power supply reset the XSCF.

System Reset:

The detection of an error reset the XSCF.

Panel:

Operating a switch on the operator panel caused a power event.

Scheduled:

Setting the TOD timer caused a power event.

RCI:

The ID device connected to the RCI caused a power event.

AC Restored:

Power recovery turned on the power supply.

Operator:

An operator's instruction caused a power event.

Poweron Restart:

Retrying power on operation turned on the power supply.

Power Failure:

A power interruption cut off the power supply.

SW Request:

An OS instruction caused a power event.

Alarm:

The server environment or a hardware fault caused a power event.

Fatal:

Fatal caused a power event.

Panic:

Panic caused a power event.

Domain ID for power event (DID)

Mode switch status on the operator panel (Switch). The following lists the
switches and their meanings: