4 domain power off, Domain power off 4–12 – FUJITSU SPARC M4000 User Manual

Page 220

Advertising
background image

4-12

SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008

2. Use the poweron (8) command to turn on power to the specified domain.

<Example 1> Turn on power to the specified domain.

XSCF> poweron -d 0

DomainIDs to power on:00

Continue? [y|n] :y

00 :Powering on

*Note*

This command only issues the instruction to power-on.

The result of the instruction can be checked by the

"showlogs power".

<Example 2> Cancel domain power on in progress.

XSCF> poweron -d 0

DomainIDs to power on:00

Continue? [y|n] :n

XSCF>

4.4.4

Domain Power Off

Command operation

1. Use the showdomainstatus (8) command to check the power status of all

domains.

XSCF> showdomainstatus -a

DID Domain Status

00 Running

01 Running

02 Running

03 Powered Off

Advertising