TABLE 1-1

XSCF-LAN Operation Examples 1

LAN Name

Operation

XSCF-LAN0 port

• For system administrator operation
The system administrator can control the server, control
domains, and display the console using the XSCF Shell.

XSCF-LAN1 port

• For field engineer operation
Field engineers can configure the server and perform
maintenance tasks using the XSCF Shell.
• For remote maintenance service operation

TABLE 1-2

XSCF-LAN Operation Examples 2

LAN Name

Operation

XSCF-LAN0 port

• For system administrator operation
• For remote maintenance service operation

XSCF-LAN1 port

Not used

1-14

SPARC Enterprise Mx000 Servers XSCF User’s Guide • April 2008

Note –

The serial port is used by maintenance engineers.

TABLE 1-3

XSCF-LAN Operation Examples 3

LAN Name

Operation

XSCF-LAN0 port

• For system administrator operation
• For maintenance operation
• For remote maintenance service operation

XSCF-LAN1 port

Same as above

Caution –

IMPORTANT

- The IP address of XSCF-LAN#0 and the IP address of

XSCF-LAN#1 must be specified in different subnet addresses.

Note –

The two XSCF-LAN ports are used for the same purpose (alternate path

configuration). For details on these connections, see

Chapter 3

.