2041

Can not repeat field if progressive

Repeat field operation is only supported in interlaced video formats.

2050

Horizontal total too small

The video format’s total (active + blanked) number of pixel clock cycles per horizontal scan
line is below the minimum number supported by the generator hardware configuration.

2059

Invalid Mode

The video format setting is incompatible with the interface selected.

2060

Horizontal total too large

The video format’s total (active + blanked) number of pixel clock cycles per horizontal scan
line is greater than the maximum number supported by the generator hardware
configuration.

2061

Invalid pixel repetition value

The value specified by the NPPP (number of pixels per pixel) to set the repetition factor for
active lines is invalid.

2062

Invalid pixel and clock values

The value specified by the NCPP (number of clocks per pixel) to set the number of clocks
per pixel is invalid.

2063

Invalid embedded aspect ratio

The value specified by the EXAR (extended aspect ratio) parameter is invalid.

2064

HDMI 5V pin is bad

The 5V pin of the HDMI connectors (Pin 18) is monitored by the generator. If the generator
does not detect the 5V on this pin it will issue this error.

2065

Invalid specified border

The value specified for XLBW (left border width), XRBW (right border width), XTBH (top
border height), or XBBH (bottom border height) is invalid.

2066

Invalid XAFD value

The value specified for the active format descriptor (XAFD) parameter was out of range.

2067

Invalid SXEX value

The value specified by the signal from extended aperture map is invalid.