Quantum Data 881 User Manual

Page 687

Advertising
background image

881/882 Video Test Generator User Guide

(Rev A.22)

571

8. Enable or disable the visibility setting by pressing the soft key adjacent to the Visible

item on the display. A + indicates visibility is enabled; a - indicates it is disabled.
Enabling the visibility setting will allow you to see the pulse position on a monitor.

To position the probe pulse in a specific location in the video signal:

1. Press the

Tools key. The following menu appears on the generator’s display:

2. Choose the

Pulse item by pressing the adjacent soft key. The current probe settings

appear on the generator’s display as shown below:

3. Select the travel sensitivity of the positioning keys by pressing the soft key adjacent to

the desired setting. Refer to the table below.

4. Set the horizontal position of the probe pulse by pressing the soft key adjacent to the

Left or Right item on the generator’s display.

The horizontal position of the probe is simultaneously displayed in two different ways:

The horizontal position P:

nnnn is given in pixels relative to the leading edge of the

horizontal sync.

If the leading edge of the probe is within the active portion of a line, an alternate
horizontal position X:

nnnn is also displayed, indicating the number of pixels

between the start of active video (X:0) and the leading edge of the probe pulse in
the horizontal direction.

5. Set the vertical position of the probe pulse by pressing the soft key adjacent to the Up

or Down item on the generator’s display.

The vertical position of the probe is simultaneously displayed in two different ways:

The vertical position

L:nnnn is given in whole scan lines relative to the leading edge

of blanking of the frame or first field.

Setting

Sensitivity

EXP

exponential increase/decrease when +/- keys are pressed

1

increase/decrease by 1 line or pixel when +/- keys are pressed

10

increase/decrease by 10 lines or pixels when +/- keys are pressed

100

increase/decrease by 100 lines or pixels when +/- keys are pressed

System
Sequence
Probe
AFC

Probe

Left

P:0000 Exp

Right X:0000

1

Up

L:0000

10

Down

Y:0000 100

Advertising
This manual is related to the following products:

882