To run the 2c-04 hdcp compliance test, On an hdmi sink (receiver) – Quantum Data 881 User Manual

Page 637

Advertising
background image

881/882 Video Test Generator User Guide

(Rev A.22)

619

2. For the 882CA connect an HDMI cable from the sink device under test input to the 882

HDMI Tx 1 port.

The following diagram depicts the test setup for the 882CA:

3. Ensure that the 882 settings used for the 2C-0x series described in

To run the 2C

series HDCP compliance test on an HDMI sink (receiver):

” on page 613, are

maintained during this test. This includes selection of the HDMI interface, selection of
the key PCP parameters such as the device type, etc.

4. To run 2C-01 tests using the short read, enter the following commands:

CPTX:CRIP 0

// Specifies short read.

CPTX:CPTU

// Initiates the execution of the test.

5. To run 2C-01 tests using the combined read, enter the following commands:

CPTX:CRIP 1

// Specifies combined read.

CPTX:CPTU

// Initiates the execution of the test.

Refer to

To view the HDCP compliance report:

” on page 651 for procedures on how to

view the generated report.

To run the 2C-04 HDCP compliance test on an HDMI sink (receiver):

For the 882E releases prior to 2.17.x, the 2C-04 tests are required to be run with 6
different set ups through the command line. There are two read configurations: 1) short
read and 2) long read and there are three encryption pulse configurations: 1) in the
beginning of the vertical blanking; 2) in the middle of the vertical blanking and 3) at the
end of the vertical blanking.

HDMI/HDCP

Source

882CA

Sink

DUT

HDMI Out

Advertising
This manual is related to the following products:

882