Quantum Data 881 User Manual

Page 690

Advertising
background image

574

Chapter 19 Using Special Sync Output

3. Set the frame pulse polarity (either 0 for low or 1 for high) by entering the following

command:

FSPP

1

4. Set the frame pulse pixel width by entering the following command:

FSPW

100

// range: 1 pixel to

HTOT

- 1

5. Set the frame pulse delay by entering the following command:

FSPD

10

// range: 0 <=

FSPD

< (

VTOT

-

FSPW

- 1); default = 0

6. Save these settings by entering the following command:

ALLU

To configure line sync on the special sync output:

1. Enable the line sync signal by entering the following commands:

FSPG

0

PSPG

0

LSPG

1

ALLU

The value of composite sync (

%# !

) does not matter once these are set.

2. Set the line sync pulse polarity by entering the following command:

LSPP

1

// 1 = high (default)

ALLU

To configure composite sync on the special sync output:

1. Enable digital composite sync by entering the following command:

SSST

2

//(or 6,11)

2. Enable the composite sync signal by entering the following commands:

FSPG

0

PSPG

0

LSPG

0

CSPG

1

ALLU

3. Set the composite sync pulse polarity by entering the following commands:

CSPP

1

// 1 = high (default)

ALLU

Advertising
This manual is related to the following products:

882