Quantum Data 881 User Manual

Page 278

Advertising
background image

260

Chapter 9 Analyzing Digital Sources and Cables

To analyze an external HDMI/DVI signal for pixel errors:

1. Connect the HDMI/DVI transmit device to an HDMI IN connector on the generator.

2. Press the

Interface key repeatedly until the following menu appears:

3. Choose the HDMI IN connector to which the transmit device is connected by pressing

the adjacent soft key.

4. (HDMI only) If desired, monitor the video signal received on the HDMI IN connector

(see

Monitoring HDMI 1.3 analyzer signal input

” on page 239).

5. Press the

Tools key. The Tools menu appears on the generator’s display as shown

below.

6. Choose the

Analyzer item by pressing the adjacent soft key. The Analyzer menu

appears on the generator’s display as shown below.

7. Choose the

PIX-ERR item by pressing the adjacent soft key. The Pixel Error menu

appears as shown below.

8. (Optional) To generate a report during the test use the following procedures.

a. Press the

Options key. The following appears on the display.

b. Enable reports by pressing the soft key adjacent to

Generate Report item so that

there is a “+” sign next to it.

HDMI IN 1
HDMI IN 2

*

System
Sequence
Probe
AFC

Analyzer

Reports

ImgShift

Timing
CableTest

PIX-ERR

PRN-ERR

*

ReadRGB

Start
Settings

Exit !

!

+Generate Report
->Auto Capture

Advertising
This manual is related to the following products:

882