Quantum Data 881 User Manual

Page 364

Advertising
background image

346

Chapter 10 Testing HDMI Sink Devices

Note: The contents of the appropriate InfoFrame output appears on the HDMI display.

Alternatively, to select an image version using the command line interface, enter the
following commands:

ISUB

1

// Enables sub images

IVER

1

// Specifies the first image version

IMGU

// Activates the image version

5. Select additional InfoFrame subimages (as desired) to verify proper InfoFrame

handling.

6. When testing is complete, disable image versions by pressing the

Options key and

choosing

More until a - appears next to it.

Alternatively, to disable image versions using the command line interface, enter the
following command:

ISUB

0

// Disables sub images

To generate a report for the PacketTx image:

1. Press the

Tools key. The Tools menu appears on the generator’s display as shown

below.

2. Choose the

Reports item by pressing the adjacent soft key. The Reports menu

appears on the generator’s display as shown below.

3. Choose the

Packets item by pressing the adjacent soft key. The Packet menu appears

on the generator’s display as shown below.

Note: Be sure that you have transferred any existing PacketTx reports to your PC
otherwise generating a new report will overwrite the existing report.

System
Sequence
Probe
AFC

Analyzer

Reports

ImgShift

EDID

Packets

!TxPacket
!RxPacket

Advertising
This manual is related to the following products:

882