Quantum Data 881 User Manual

Page 174

Advertising
background image

156

Chapter 4 Networking Generators

2. Open a second Web browser. You now have two instances of the Generator FTP

Browser running: one for the source generator and one for the target generator.

3. In the Generator FTP Browser window for the target generator, delete all of the files in

the target generator’s flash memory as follows:

a. In the

Instrument Files area, click the down arrow by the Look in box and select

tffs0. This is the target generator’s flash memory.

b. Select all of the System and Library folders in the lower pane.

c. Click the

Delete button. A confirmation dialog box appears.

d. Click

OK to delete the files.

4. Copy all of the files in the source generator’s flash memory to the target generator’s

flash memory as follows:

a. In the

Instrument Files area of source generator’s Generator FTP Browser

window, click the down arrow by the

Look in box and select tffs0. This is the source

generator’s flash memory.

b. Select the System and Library folders in the lower pane.

c. Hold down the SHIFT key and drag the selected folders to the

Instrument Files

area of the target generator’s Generator FTP Browser window. A confirmation
dialog box appears.

d. Click

OK to copy the files.

Advertising
This manual is related to the following products:

882