Quantum Data 881 User Manual

Page 651

Advertising
background image

881/882 Video Test Generator User Guide

(Rev A.22)

633

CPTX:DUTT 3

// specifies the device under test as a repeater

for test 3AB.

You can query the current value of the parameter with:

CPTX:DUTT?

// returns the device under test type.

11. (Optional) Specify the remaining parameters in the

EditPCP menu using the table

above.

Alternatively, you can specify the parameters through the command line as follows:

CPTX:RPFT 0

// indicates whether DUT (repeater) supports 1.1

features such as Advanced Cipher and Enhanced
Link Verification. 1 = yes; 0 = no.

CPTX:RKSV 10

// specifies maximum number of downstream devices

that can be supported in the repeater’s KSV list

CPTX:ROOR 0

// indicates whether DUT (repeater) outputs outputs

content to the downstream repeater that does not
have any downstream device connected.
1 = yes; 0 = no.

CPTX:SRCZ 0

// indicates whether the 880 should use a downstream

device count of 0 or the device count as specified
by the SKSV command.
Note that this parameter is only used for the
3B-01 test and this test should be run for both
settings: 0 or 1 (use setting of SKSV).

12. Press the

Options key to save the capabilities definition.

The generator LCD will display the message “Saved”.

13. Press the

Tools key get back to the Reports menu.

The generator LCD will display the reports menu as shown below.

14. Select

HDCP to access the HDCP compliance test menu.

The following is displayed on the generator’s LCD.

15. Select

!CompRpt to initiate the HDCP compliance test.

The message “HDCP Compliance Test” is shown and then all the tests are shown in
sequence.

Alternatively, you can run the tests using the following command:

EDID

Packets

Misc

HDCP

!CompRpt

EditPCP

Advertising
This manual is related to the following products:

882