881/882 Video Test Generator User Guide (Rev A.22)

505

To set up the generator for DisplayPort:

1. Connect the generator to the DisplayPort device as follows:

a. Sink Testing - The illustration below depicts the setup for monitoring the link layer

transactions during testing of a DisplayPort sink:

b. Source Testing - The illustration below depicts the setup for monitoring the link layer

transactions during testing of a DisplayPort sink:

2. Activate the DisplayPort interface by pressing the

Interface key and choosing the

DisplayPort interface as shown below.

Alternatively, to activate the interface through the command line interface, enter the
following commands:

XVSI

10

// Activates the DisplayPort interface

DispPort*