Configure generator to log cec messages – Quantum Data 881 User Manual

Page 381

Advertising
background image

881/882 Video Test Generator User Guide (Rev A.22)

363

CECX:CECP /tffs0/Library/CECData/

2. Create a custom instance of a CEC device for CEC1 using the following commands:

CEC1:CECN <name> //e.g. myTV1
CEC1:CECB

//begins the CEC editing session

3. Configure the custom CEC device parameters using the following commands:

CEC1:PA 0 0 0 0

//configures the device physical address

CEC1:PT 1

//configures the product (device) type

The table below lists the device (product) types and their codes.

CEC1:VID <vid>

//configures the device vendor ID

CEC1:OSDN

//configures the device OSDN

CEC1:PA 0 0 0 0

//configures the device physical address

4. Save the custom CEC device to a file:

CEC1:CECE

//ends the CEC editing session

CEC1:CECS

//saves the CEC device

5. Assign the custom CEC device to a connector:

CEC1:CECL myTV

//assigns myTV to HDMI Rx port

CEC1:CECU

//configures (uses) the assigned device

Configure generator to log CEC messages

The 882 can be configured to log CEC message and store them in a user defined
directory.

To enable CEC logging:

1. Enter the following command to enable logging on the HDMI connector:

CEC1:LOGG 1

//enables logging on the HDMI Tx output 1 port

CEC3:LOGG 1

//enables logging on the HDMI Rx ports

2. Enable all logging with the following command:

CECX:LOGM 6

//enables logging of all CEC messages

To disable CEC logging:

1. Enter the following command to disable CEC logging:

Device Type

Device Code

TV

0

Recording Device

1

Set Top Box

3

DVD

4

Audio System

5

Advertising
This manual is related to the following products:

882