Reading pixel data – Quantum Data 881 User Manual

Page 297

Advertising
background image

881/882 Video Test Generator User Guide (Rev A.22)

279

XVSI

4 (or 3)

// Selects the HDMI-H or HDMI-D interface

ALLU

// Applies the interface setting to the generator

5. Enter the following commands to load a valid HDMI or DVI format into the analyzer.

FMTL DMT0660

// loads the DMT0660 (e.g.) format into the edit buffer

FMTU

// applies the format to the generator/analyzer

6. Enter the following commands to setup the measurement of pixel data.

PDAX:FRMS

100 //sets the number of frames to analyze in the pixel

data analysis test to 100

PDAX:MXER

1000 //sets the maximum number of errors to record in pixel

data analysis test to 1000

PDAX:RPTG

1

//enables the generation of reports for the ppixel

data analysis test

PDAX:REFG

0

//enables auto reference capturing for the pixel

data analysis test

PDAX:CAPF

//captures a frame of pixel data for the pixel

data analysis test

7. Enter the following commands to initiate the pixel data measurement test.

PDAU

//runs the pixel data analysis test

8. Enter the following command to query for the results of the pixel data measurement

test.

PDAX:ERRQ

? 10 100

//retrieves 100 errors starting at the 10th error

in the index.

2, 110, 220, 128, 255, 64, 129, 250, 64 // shows the results

9. Enter the following command to query for the number of detailed error records.

PDAX:NERR

?

//retrieves number of detailed errors recorded.

111

// shows the results

Reading pixel data

The following is an example of using commands to read the pixel component values of a
captured frame from an HDMI/DVI transmit device.

To view specific timing information of an external HDMI/DVI source signal:

1. Connect the HDMI/DVI transmit device to an HDMI IN connector on the generator.

2. Using a terminal emulator, establish a terminal connection with the generator. Refer

to

Establishing a terminal session with the generator

” on page 31.

3. Choose the connector to which the transmit device is connected by entering the

following commands:

XVSI:IN

1

// Selects the HDMI-1 input connector

ALLU

// Applies the interface setting to the generator

4. Choose the

HDMI-H (or HDMI-D) item by entering the following commands: