Pixel rate too low

The video format’s total (active + blanked) number of pixel clock cycles per horizontal scan
line multiplied by the horizontal scan rate is less than the minimum pixel clock frequency
supported by the generator hardware configuration for the format video type.

2082

Number of bits not allowed

The generator hardware configuration does not support the number of data bits per color
for the serial digital video type selected in the video format.

2083

Invalid quantizing mode

An invalid value has been specified for the digital video quantizing mode (DVQM)
parameter.

2084

Invalid Pixel Repetition

In digital mode, double clocking is not supported for this specific hardware. This error may
be the result of an older FPGA or hardware.

2085

Invalid Sampling Mode

The value specified for digital video sampling mode (DVSM) is not valid and is inconsistent
with the setting of digital video signal type (DVST).

2086

Invalid Video ID Code

The value specified for the CEA-861 Video Identification Code (VIC) with the DVIC
parameter is invalid.

2087

Invalid Number of Bits per Audio Sample

The value specified for number of bits per audio sample (NBPA) is invalid.

2088

Invalid Sampling Rate

The value specified for audio sampling rate (ARAT) is invalid.

2089

Invalid Number of Audio Streams

The value specified for number of audio streams (NDAS) is invalid.

2090

Horizontal total not even

The generator hardware configuration does not support interlaced video formats with a
total (active + blanked) number of pixel clock cycles per horizontal scan line that is not
evenly divisible by 2.