414

Chapter 12 CEC Compliance Testing

CEC Device Bridge- Model TPA-CEC-4R.

Use the table below to determine the correct test device needed for each test.

Load

Application

1

Connects CEC line to DDC/CEC ground via a 1 MegOhm +/-5% resistor

2

Connects CEC line to 3.63V via a 27kohm ±5% resistor (multimeter in parallel with the
resistor to measure the voltage drop; alternate (preferred) position for measuring the CEC
line leakage current

3

Connects CEC line to 3.3v via a 27kohm ±5% resistor

4

Connects CEC line to DDC/CEC Ground via 1kO ±5%

5

Connects CEC line to 3.63V via a 27kohm ±5% resistor (multimeter in series with the
resistor to measure the CEC line leakage current)

6

Measures open-circuit voltage across the CEC bus with the Multimeter (debugging only
and does not correspond to any official HDMI CTS test)

Test ID

Test Device

7-1: CEC Bus Logic ‘0’ and ‘1’ Voltage Level

TPA-CEC-RR

7-2: CEC Maximum Rise Time and Fall Time

TPA-CEC-RR

7-15: CEC Line Degradation

TPA-CEC-R

8-14: CEC Line Degradation

TPA-CEC-R

CEC Device Bridge

Model TPA-CEC-4R

Port 3

Port 1

Port 2

Port 4

Source

Sink

DUT

DUT

TE In 1

TE Out 1

TE Out 2

TE Out 2

TE Out 1

TE In 1

Advertising
This manual is related to the following products:

882